← Search

PITOT TUBE FLOW METER

ClassOfInanimatePhysicalObject

http://data.posccaesar.org/rdl/RDS820979

hasCreationDate2006.01.17
hasCreatoru20683
hasDefinitionA differential pressure flow meter utilizing a pitot tube (a probe with an open tip) that is inserted into the flow field.
hasDesignationPITOT TUBE FLOW METER
hasIdPCARDS820979
hasNoteThe Pitot Static tube measures the total pressure (or impact pressure) at the tip of the Pitot tube and the static pressure of the flow at side ports. The difference of these pressures, i.e. the dynamic or velocity pressure (Pdynamic), varies with the square of the gas velocity.
hasStatusQualified

Referenced by (8)

ResourceVia
RDS17552894hasSuperclass
RDS17603820hasSuperclass
RDS17914140hasClassified
RDS3780622hasClassOfWhole
RDS3937311hasSubclass
RDS6102295hasRepresented
RDS6175066hasRepresented
RDS999542491hasRepresented