ClassOfInanimatePhysicalObject
http://data.posccaesar.org/rdl/RDS880424
| hasCreationDate | 2006.06.08 |
|---|---|
| hasCreator | u20683 |
| hasDefinition | A positive displacement flow meter that is using two gear wheels fitting in a meter body to measure flow rate. |
| hasDesignation | GEAR POSITIVE DISPLACEMENT FLOW METER |
| hasIdPCA | RDS880424 |
| hasNote | The liquid stream is divided into the fixed volume cavities between the gear teeth and meter body. The upstream liquid pressure continuously fills the cavities and forces the gears to rotate away from the inlet. The volumes of liquid are then squeezed out from between the teeth as they re-mesh on the outlet side of the flow meter. Each revolution o |
| hasStatus | Qualified |
| Resource | Via |
|---|---|
| RDS17907680 | hasClassified |
| RDS3950027 | hasSubclass |
| RDS6105916 | hasRepresented |
| RDS6174488 | hasRepresented |
| RDS7497122 | hasClassOfWhole |
| RDS999542163 | hasRepresented |