← Search

RDS999208893

ExpressString

http://data.posccaesar.org/rdl/RDS999208893

hasCreationDate2006.10.01
hasCreatorMIG261
hasDefinitionA head which is measured at a suction flange and corrected to the datum elevation. NPSHR at rated and other capacities is equal to the NPSH that produces a 3 percent head drop (first stage head in multistage pumps) due to the cavitation within the pump. NPSH in meters is determined by vendor testing with water.
hasIdPCARDS999208893

Referenced by (1)

ResourceVia
RDS999208892hasClassified